What Makes Our Fundus Camera Different?
Discover our key technological advantages in image resolution, automated workflow, and patient adaptability.
8MP Ultra-High Resolution Imaging
Traditional Challenge
Our Advantage

One-Touch Fully Automatic Capture
Traditional Challenge
Our Advantage

Non-Mydriatic & Small Pupil Friendly
Traditional Challenge
Our Advantage

Target Clinical Applications
Ophthalmology Clinics & Hospitals
Delivers high-resolution 8MP retinal images and multi-angle fixation to assist clinicians in routine fundus examination and pathology tracking.
Primary Care & Diabetes Screening
Ideal for primary clinics and endocrinology departments. Enables fast, non-mydriatic screening for early diabetic retinopathy detection.
Health Examination Centers
One-touch fully automated dual-eye imaging allows non-specialist staff to operate easily, dramatically boosting daily screening throughput.
Optometry & Optical Stores
Enhances comprehensive eye care services by offering clear retinal documentation and visual consultations for patients during vision exams.
Clinical Imaging: Precision Retinal Performance
Captures high-definition views of retinal microvasculature, macula, and optic disc with a wide 50° FOV for reliable clinical assessment.
Guides patient sightlines with 9 adjustable internal fixation targets to easily document central, macular, and peripheral retinal areas.
Advanced optical design allows effortless retinal capture without pupil dilation, enabling smooth examinations for small pupils (≥ 0.13 in).
Built-in software features allows clinicians to adjust Gamma, contrast, brightness, and RGB color channels in real time for optimal lesion visibility.
Why Choose DrTono Vista Station
Compare key features and workflow advantages to see how our fully automatic solution outperforms traditional systems.
DrTono Vista Station
NIDEK AFC-330
Crystalvue NFC-700
Smart Workflow Features for Efficient Retinal Imaging
Designed to simplify retinal image capture, transfer, storage, and review with flexible digital workflow solutions.
Auto-Tracking & Smart Alignment
Automated target alignment and autofocus guide swift positioning, ensuring precise eye tracking and steady capture.

One-Touch Automated Capture
Supports rapid, automated binocular capture with built-in OD/OS auto-switching, significantly speeding up daily patient exams.

Patient Data & File Management
Built-in patient database allows effortless record creation, search, and local file management for streamlined clinical documentation.

Dual-Screen Real-Time Visualization
Displays live imaging on the integrated touchscreen while seamlessly mirroring high-resolution views to an external HD monitor.

Smart Analysis & Touchscreen Review
Review captured images using multi-touch gestures, while built-in software tools allow precise measurement of cup-to-disc ratio and lesion area.

Product Specifications
| Type | Automated Non-Mydriatic Desktop Fundus Camera | Image Resolution | 3264 × 2488 pixels (8 MP) |
| Field of View (FOV) | 50° | Minimum Pupil Diameter | ≥ 0.13 in (3.3 mm) |
| Working Distance | 1.38 in (35 mm) | Focus Mode | Auto / Manual Alignment & Focus |
| Refractive Compensation | -20 D to +20 D | Fixation Targets | 9-Point Internal Fixation |
| Illumination Source | White LED / Near-Infrared LED | Operation Mode | One-Touch Bilateral Capture |
| Exposure Control | Auto / Manual | Image Format | JPEG |
| Color Rendering Index | CRI (Ra) ≥ 85 | Power Supply | AC 100–240 V, 50/60 Hz |
Frequently Asked
Questions
Find answers to common questions regarding device specifications, ordering, PO submissions, and technical support.
Have more questions? Contact our teamYes. DrTono Vista Station supports non-mydriatic retinal imaging and can capture images with a minimum pupil diameter of ≥ 0.13 in (3.3 mm) under appropriate examination conditions.
Vista Station captures 3264 × 2488 (8 MP) retinal images with a 50° field of view and supports imaging with a minimum pupil diameter of ≥ 0.13 in (3.3 mm).
Average delivery time is 7–14 business days, depending on your destination. Once your order has shipped, we’ll email you a tracking number so you can follow its delivery status.
All DrTono devices include a 2-year limited warranty covering manufacturing defects that occur under normal use. Please see our Warranty Policy for full coverage details and exclusions.
Of course. If you are not satisfied with your device, you may request a refund within 30 days of receiving it. For complete details and eligibility requirements, please review our Return Policy.
Yes. We accept purchase orders from qualified medical institutions. Please send your PO to info@drtono.com for review, and our team will contact you after it has been reviewed.
Clinical Service & Purchase Commitments
Factory-Certified New
100% brand-new units with rigorous pre-shipment optical calibration.
Clinical Standards
Engineered for professional ophthalmic screening requirements.
30-Day Evaluation
Evaluate the system in your practice with full return flexibility.
2-Year Warranty
Full system coverage with priority technical support for practices.
Insured Express Shipping
Complimentary door-to-door delivery with full transit insurance.
Connect with Our Medical Team
Have questions about DrTono Vista Station? Leave your details below and our clinical specialists will reach out shortly.